Home Storage8 min readUpdated 3 October 2026By STORASTRA ENERGY

Sizing a home battery is not about buying the biggest box you can afford. It is about matching two independent numbers: how much energy you need (kWh) and how much power you need at any instant (kW). Get either wrong and the system disappoints.

The two numbers that matter

  • Capacity (kWh) — how long the battery can run your loads. This is the "fuel tank".
  • Power rating (kW) — how many loads it can run at the same time. This is the "engine".

A 10kWh battery with a 3kW inverter cannot run a 5kW air conditioner, no matter how much capacity is left. A 5kW inverter with a 5kWh battery will run the air conditioner beautifully — for about an hour.

Step 1: Read your electricity bill

Find your average daily consumption in kWh. Divide the monthly total by 30. Typical figures:

Home profileDaily consumptionTypical battery size
Apartment / small home8–12 kWh/day5 kWh
Standard family home15–25 kWh/day10 kWh
Large home with A/C30–50 kWh/day15–20 kWh
Home with EV charging40–70 kWh/day20 kWh+ or dedicated charger

Step 2: Decide what you are solving for

Three different goals produce three very different sizes:

  • Solar self-consumption — store daytime surplus for evening. Size to roughly 50–70% of daily consumption.
  • Backup during outages — size from your critical load list and the outage duration you want to survive.
  • Time-of-use arbitrage — charge off-peak, discharge at peak. Size from your evening peak-window consumption.

Step 3: Build a critical load list

List what must stay on during an outage, with wattage and hours. Wattage is usually on the appliance label.

LoadTypical power8 hours overnight
Lighting (LED, whole home)100–200 W0.8–1.6 kWh
Refrigerator / freezer150–400 W (cycling)1.2–2.5 kWh
Router, modem, IT30–80 W0.3–0.6 kWh
TV + media100–250 W0.8–2.0 kWh
Well pump700–1,500 W1.0–2.0 kWh (intermittent)
Air conditioner (12,000 BTU)1,000–1,500 W8–12 kWh
Electric stove / oven2,000–3,500 WOnly if cooking during outage
Watch the starting surge. Motors and compressors draw two to three times their running wattage for a second or two. Size the inverter for the surge, not just the running load.

Step 4: Convert to usable capacity

Battery capacity is quoted as nominal, but you should not plan to use all of it. With LiFePO4 at a recommended depth of discharge below 80%:

Usable kWh = nominal kWh × 0.8 × inverter efficiency (typically 0.92–0.95)

So a 10kWh LiFePO4 bank delivers roughly 7.4–7.6 kWh of usable AC energy. Working backwards: if your overnight critical loads total 7kWh, you need about a 10kWh nominal bank.

Worked example

A family home uses 20 kWh/day and wants backup for lighting, refrigeration, internet, a few sockets and one bedroom A/C through an 8-hour night.

  • Lighting 0.4 kWh + fridge 1.6 kWh + IT 0.5 kWh + sockets 1.0 kWh + A/C 8.0 kWh = 11.5 kWh
  • Divide by 0.8 depth of discharge → 14.4 kWh nominal
  • Divide by 0.93 inverter efficiency → ~15.5 kWh nominal battery
  • Simultaneous peak (fridge + A/C + lighting + sockets) ≈ 2.5 kW, with A/C start surge ≈ 4 kW → 5 kW hybrid inverter

That points to a ~15kWh stackable LiFePO4 system with a 5kW hybrid inverter — comfortably inside the configurable range of our home energy storage system.

Match the solar array as well

A battery that never fully charges is wasted money. As a rough guide, you need about 1–1.5 kW of solar per 5 kWh of battery in a sunny climate, and 2–2.5 kW per 5 kWh in a cloudy or high-latitude one. In winter, output can drop to a third of summer, so size for the worst month you actually care about.

Five sizing mistakes we see repeatedly

  1. Sizing on nominal kWh and forgetting depth of discharge — the system feels 25% smaller than expected.
  2. Ignoring surge current — the inverter trips when the pump or A/C starts.
  3. Oversizing for solar self-consumption — the top of the battery never cycles, so that capacity never earns anything.
  4. No critical-loads sub-panel — the battery tries to run the whole house and empties in two hours.
  5. Forgetting future loads — an EV or a heat pump arrives in year two and the system is suddenly undersized. Choose stackable capacity where you can.

Not sure which size fits your project? Send us your last three electricity bills and your critical load list via the inquiry form and we will size it for you.

FAQ

Most family homes land between 10kWh and 15kWh. Homes that only want evening solar self-consumption often sit at 5–10kWh; homes backing up air conditioning usually need 15kWh or more.

With about 7.5kWh of usable energy, a 10kWh LiFePO4 system runs essential loads (lighting, refrigeration, internet, sockets) for roughly 8–12 hours. Adding air conditioning typically cuts that to 4–6 hours.

Yes, if you choose stackable or modular LiFePO4 modules from the start. Plan the inverter power rating for your final capacity, since that is the part that is expensive to change later.

Related product: Home Energy Storage System — full specification and inquiry options. Or send us your requirements and we will confirm the configuration.